Task #3158

open
TJ SD

Task #2998: Assembly

D-Sub 25 Cable Preparation

Task #3158: D-Sub 25 Cable Preparation

Added by Thomas Joseph about 2 months ago. Updated 25 days ago.

Status:
Resolved
Priority:
Normal
Assignee:
Start date:
19/01/2026
Due date:
22/01/2026 (48 days late)
% Done:

100%

Estimated time:
Spent time:

Description

Prepare 4 cables with female strip header terminated at other end.
This is for use with Test Setup


Files

Media (11).jpg (539 KB) Media (11).jpg Surendra Naik, 20/01/2026 06:17 AM
Media (6).jfif (518 KB) Media (6).jfif Sumanth D, 21/01/2026 11:34 AM
Media (7).jfif (395 KB) Media (7).jfif Sumanth D, 28/01/2026 04:42 AM
Media (11).jpg

SN Updated by Surendra Naik about 2 months ago Actions #1

Media (11).jpg

For testing purposes, a D-sub 25 female connector with wiring is ready.
For delivery purposes, we do not have the cable and connector with PVC duct; we need to purchase them

SD Updated by Sumanth D about 2 months ago · Edited Actions #2

  • Status changed from In Progress to New
  • Assignee changed from Surendra Naik to Sumanth D
  • % Done changed from 30 to 40

https://elpisit-my.sharepoint.com/:b:/g/personal/satish_sl_elpisitsolutions_com/IQCOnc7dWER0SrhfxGcHYO8tAQL3TF964MX0zlTWt_dkNXo?e=FMqJ76

Please find the Wiring diagram for preparing D-Sub 25 pin connectors for sensor interface for delivery.

SD Updated by Sumanth D about 2 months ago Actions #3

  • Assignee changed from Sumanth D to Surendra Naik

SD Updated by Sumanth D about 2 months ago · Edited Actions #4

  • Assignee changed from Surendra Naik to Sumanth D

The above mentioned is for Hydrofab and we cant use this for Core4 project.

Due to lack of cables, to continue testing I used a single 4 core cable for two channels by cutting them into two with shorter length. Existing is of 1mtr length
With this I prepared AI and AV D-sub connector.

For DI and DO tomorrow I will complete.

TJ Updated by Thomas Joseph about 2 months ago · Edited Actions #5

  • Due date changed from 19/01/2026 to 21/01/2026

Cable shortage, Due date extended to procure cable and assemble

TJ Updated by Thomas Joseph about 2 months ago Actions #6

  • Status changed from New to In Progress

TJ Updated by Thomas Joseph about 2 months ago Actions #7

  • Due date changed from 21/01/2026 to 22/01/2026

SD Updated by Sumanth D about 2 months ago Actions #8

D-Sub cables for testing AI,DI,DO was completed. This is for internal testing only. Once the 4-core cables received, final delivery cables with labeling will be arranged

TJ Updated by Thomas Joseph about 2 months ago Actions #9

The cable end is open. to prevent short circuit, suggest to use female connector at cable end, male at test setup so that device will be protected always

TJ Updated by Thomas Joseph about 2 months ago Actions #10

For the delivery, decide cable length after confirmation from customer

SD Updated by Sumanth D about 1 month ago · Edited Actions #11

  • % Done changed from 50 to 70

For testing purpose the D-sub cables were ready.

SD Updated by Sumanth D about 1 month ago Actions #12

TJ Updated by Thomas Joseph 25 days ago Actions #13

  • Status changed from In Progress to Resolved
  • % Done changed from 70 to 100

As part of the updated requirements that AI, DI, DOs not going to use with sensors, and also cable not part of deliverables in PO, this task is resolved