Bug #3361

open

LED not functioning as per the requirements

Bug #3361: LED not functioning as per the requirements

Added by Jagatheswaran J about 2 months ago. Updated about 1 month ago.

Status:
In Progress
Priority:
Normal
Target version:
-
Start date:
09/03/2026
Due date:
18/03/2026 (47 days late)
% Done:

90%

Estimated time:
Severity:
Minor

Description

Requirements -Status Indicators

  1. LED1 – Red (Power Status)

Device Power ON – ON

Device Power OFF – OFF

  1. LED2 – Orange (4G Status)

Data Posting to Server – Orange Blink

Network Failure / Socket Not Connected – OFF

Network OFF – Orange Blinking Continuously

  1. LED3 – Green (USB Status)

USB Connected to Tool – ON / Green Blink

Data Transfer – Green Blinking

Config Tool Disconnected – OFF

  1. LED4 – Blue (Modbus Status)

Modbus Data Reading – Blue Blink

LAN Cable Connected – ON

LAN Cable Disconnected – OFF

Socket Error – Blinking Continuously

During device booting, all LEDs will blink 5 times.

Updated by Sunder Venugopal about 2 months ago Actions #1

  • Status changed from New to In Progress

Updated by Jagatheswaran J about 2 months ago Actions #2

  • Subject changed from LED notfunctioning as per the requirements to LED not functioning as per the requirements
  • % Done changed from 0 to 90

The issue has been fixed. It needs to be verified again after code integration.

Updated by Channamallikarjuna Mattihalli about 2 months ago Actions #3

  • Assignee changed from Channamallikarjuna Mattihalli to Greeshma Rayani

Updated by Jagatheswaran J about 2 months ago Actions #4

Waiting for code integration. Once it is completed, testing will be performed and the results will be updated.

Updated by Sunder Venugopal about 2 months ago Actions #5

  • Due date set to 18/03/2026

Updated by Sunder Venugopal about 1 month ago Actions #6

23/3: Still the code is not available

Updated by Greeshma Rayani about 1 month ago Actions #7

code integration is done.There is a small change in usb led

  1. During data transfer led will blink 2 times.
  2. When error occurs in data transmission led will blink continuosly.
  3. i have updated the led functionality in document below is the onedrive link
    https://elpisit-my.sharepoint.com/:x:/g/personal/satish_sl_elpisitsolutions_com/IQAenj5K50l3TpIS8yGYuoHeAbinfWxrZxCUZn4OPBDHkjU?e=njaAdB

Updated by Greeshma Rayani about 1 month ago Actions #8

  • Assignee changed from Greeshma Rayani to Jagatheswaran J