Actions
Task #2860
openBoard Bring up
Task #2860:
Board Bring up
Added by Sunder Venugopal 4 months ago. Updated about 1 month ago.
Description
Electrical testing
Test jig with all the access points
Updated by Sunder Venugopal 4 months ago
Actions
#1
- Due date changed from 13/01/2026 to 16/01/2026
- Start date changed from 08/01/2026 to 13/01/2026
- Follows Task #2859: PCB Assembly added
Updated by Sunder Venugopal 4 months ago
Actions
#2
- Due date changed from 16/01/2026 to 06/02/2026
- Start date changed from 13/01/2026 to 03/02/2026
Updated by Sunder Venugopal 4 months ago
Actions
#3
- Precedes Task #2863: Software Testing added
Updated by Sunder Venugopal 4 months ago
Actions
#4
- Due date changed from 06/02/2026 to 29/01/2026
- Start date changed from 03/02/2026 to 26/01/2026
Updated by Sunder Venugopal 4 months ago
Actions
#5
- Due date changed from 29/01/2026 to 15/01/2026
- Start date changed from 26/01/2026 to 12/01/2026
Updated by Sunder Venugopal 4 months ago
Actions
#6
- Due date changed from 15/01/2026 to 13/01/2026
Updated by Sumanth D 3 months ago
Actions
#7
- Assignee changed from Bhavani M to Sumanth D
- % Done changed from 0 to 70
Test report for Electrical testing.
Conducted power on testing and captured SPI signals. And the results were added in the Test report.
Need to check whether Device is detecting or not for this debugger is required.
Unizen has only 2 debuggers. One is using for water meter their project and the other is using for TPMS EVB(proto type).
Updated by Thomas Joseph 3 months ago
Actions
#9
Observed that Reset resistor changed to 68K for debugger detection
@Sumanth D : Please check with @Mohan Kashyap , @Surendra Naik
Updated by Sumanth D about 2 months ago
Actions
#10
- Status changed from In Progress to Resolved
- % Done changed from 70 to 100
Updated by Sumanth D about 1 month ago
Actions
#11
The Device is connected to nRF connect app and the log file is attached and device is booting with one wire uart
Actions